Tooth Dental Harmony Infection Control Inspection
- Address
9-8685 Lundy’s Lane
Niagara Falls - Services
Dentist
Summary
Dental instruments not disassembled, packages overfilled and not labeled properly for sterilization.
Diseases resulting from similar errors in infection control may include:
- Blood-borne infections
Contact
Duty Officer
Public Health Nurse
905-980-6000 ext. 7590, toll free 1-888-505-6074
inspect@niagararegion.ca
Findings and Corrective Measures
A complaint was identified from a member of the public on November 14, 2024, related to infection prevention and control concerns.
This infection prevention and control lapse involved a member of the regulatory college.
Orally corrective measures were discussed at the time of inspection.
An initial onsite investigation was conducted on November 18, 2024.
An investigation report was given to the premise / facility noting corrective measures. Information and education was provided.
Corrected Issues
Issue | Correction | Date Corrected |
---|---|---|
Written policies and procedures are incomplete/not available for the recall of improperly reprocessed equipment. | Written policies and procedures are to be complete/available for the recall of improperly reprocessed equipment. | Nov. 29, 2024 |
Medical/dental equipment/devices not cleaned appropriately. | Clean medical equipment/devices appropriately. | Nov. 26, 2024 |
Staff have not received annual training regarding dental water lines, reprocessing and IPAC specific training and recorded. | Staff to receive annual training regarding dental water lines, reprocessing and IPAC specific training and recorded. | Nov. 26, 2024 |
Manufacturers’ instructions for use are not followed for maintenance of water delivery systems. Waterlines are not purged appropriately at the beginning of the day. | Follow manufacturers’ instructions for use for daily maintenance. Waterlines are to be purged appropriately. | Nov. 26, 2024 |
Work surfaces not appropriate. | Install appropriate work surfaces. | Nov. 20, 2024 |
Dental/medical equipment/devices not packaged to appropriately allow steam to contact all surfaces. | Package dental/medical equipment/devices to allow steam to contact all surfaces. | Nov. 20, 2024 |
Packages undergoing sterilization not labeled appropriately. | Label packages undergoing sterilization appropriately. | Nov. 20, 2024 |
Medical/dental equipment/devices not disassembled for cleaning and/or sterilization. | Disassemble medical equipment/devices before cleaning/disinfection | Nov. 20, 2024 |
Processed packages that are contaminated not reprocessed as appropriate or stored to keep from contamination. | Reprocess all contaminated processed packages and store in a manner to keep from contamination. | Nov. 20, 2024 |
Single-use items are not disposed of following use. | Dispose of single-use items following use. | Nov. 20, 2024 |
Hand sanitizer and masks not provided at reception and treatment room entrances | Hand sanitizer and masks to be available at appropriate locations throughout the clinic. | Nov. 20, 2024 |